ADR-0123: Preserve actual sediment load at nonzero inflow

Date: 2026-10-31

Status: Accepted for wepp_261029 artifact revision 4 (2026-10-31); application delivery tracked separately.

Context

Actual ROUTE/EROD/DEPOS execution confirms that the abs(qostar)<.0011 no-inflow approximation can discard incoming sediment at small, nonzero flow. For qostar=.001, incoming load.01, constant capacity.001, phi2 and zero local sediment source, first-grid load is.001 instead of the independent .0010743802 reference. The ordinary qostar1 control preserves incoming mass. This is shared routing logic; applicability extends beyond Roads.

Decision

Use the no-inflow limiting boundary only for exactly zero normalized inflow. For nonzero supported flow, compute the initial deposition rate from the actual incoming load and flow: DU=phi*(C-L)/qostar. Evaluate the arithmetic in double before converting to the existing native argument type. Preserve output formats and the separate exactly-zero formula. No erodibility, soil, transport law or particle renormalization change is proposed.

Rationale and alternatives

Zero flow and small flow carrying sediment have different boundary conditions. An arbitrary near-zero band cannot justify replacing the incoming sediment state. Returning initial excess from EROD while ROUTE still supplies DU0 would retain the same loss. Altering reported concentrations would conceal it. The existing source comment already distinguishes zero from nonzero inflow.

Evidence and acceptance

The active EROD ablation plan retains exact actual-source fixture traces and hashes. Freeze valid positive and negative flow, zero-flow, former-threshold-neighbor and ordinary controls before execution. Require actual ROUTE→DEPOS load continuity and independent solutions, not only a scalar rate calculation. Full physical/magnitude, native, Disturbed, fresh Cedar and independent review gates remain required.

Risks and rollback

The removed approximation may affect any configuration with small nonzero inflow. Extreme rates must remain explicitly diagnosed rather than silently clamped. A scientifically valid rate not representable by the current native type requires separate evidence and review. Retain isolated pre-change pairs and unchanged shipped261029 revision3 for exact comparison. No default or release has been accepted; withheld soils and the UI human gate remain intact.

Decision provenance

User/Codex repository session,2026-10-31,America/Los_Angeles. The user authorized autonomous native defect investigation/remediation and scientific review. Codex implements the ablation; independent agents review the actual source and outputs. This proposed decision has no external endorsement and is not an accepted release authorization.

Transition handoff amendment (U9)

The same actual-load boundary condition applies where EROD returns a native coordinate adjacent to a deposition root. Unconditionally passing DU0 resets load to capacity at that coordinate; an actual-chain fixture confirms a30ppm jump after the larger polynomial-cancellation error is repaired. For finite wet XDBEG+qostar, compute DU=phi*(C(XDBEG)-L)/(XDBEG+qostar). Preserve small positive rates from the supported side of the coordinate bracket; clipping them to zero would recreate the jump. At an exactly zero denominator, equality retains DU0 and the existing regular limit. Unequal load there is explicitly unrepresentable and must fail diagnostically, never lose mass silently. Reached real dry-terminal cases remain release blockers until explained or repaired. Fifteen actual-chain controls pass this candidate.

Wet-coordinate contract amendment (U11)

A confirmed legacy DEPEQS guard moves coordinates by a fixed1e-6 when abs(X+qostar)<1e-7, which can leave the physical interval and corrupt incoming load. The candidate removes that mutation. DEPOS owns exact negative-flow terminal load/rate zero; strict wet points retain their actual coordinate. Direct DEPEQS exact negative-terminal rate requests fail explicitly because the rate can diverge while the load has a finite dry limit. The regular zero-inflow origin is evaluated explicitly; DEPEND's separate root-search terminal contract remains. Tests include supported Case4 flow near terminal, negative settling-parameter limits and geometry readback, not only dry export.

Revision-4 acceptance

The exact combined pair is scientifically accepted and installed under the existing release name. Source b01a739957bef5aacf35b4a89bc13eddc9d94804 matches all 489 retained build inputs. See the scientific acceptance and revision-4 delivery. The shared native repair applies beyond Roads; it does not accept Roads parameter defaults or claim universal numerical accuracy. Historical experimental outcomes below/above retain their original scope.